To answer your question, I can tell you that the default text size is set inside the blocks as the attribute text size and width. That is why it would help to see your drawing. I have no problem with text size being converted from inches to millimeters. But note that 10mm spacing between I/O is going to crowd the text. Use 25.4 for the scale factor if inserting JIC125 or NFPA PLC symbols into a mm environment. Note: Be sure not to check the box labeled “Apply to PLC border only”. There is a scale box for that on the Insert PLC dialog. style ladder diagram, the symbols from the JIC125 or NFPA folders are sized for inches. If you are indeed using a millimeter environment with a U.S. Of course my PLC modules insert in a horizontal orientation. ![]() ![]() ![]() I use the X-zone format at 51.25mm spacing between zones, and 20mm spacing between wires. The PLC modules on my IEC drawings look just fine. Can you post a drawing or photo that illustrates the issue? When you say ladder scale I’m thinking you might mean ladder width, and then I'm thinking U.S.